Inorganic modified-clay core certified A2 non-combustible for commercial & facade envelopes.
00 / ARCHITECTURAL CLADDING SYSTEMS
Four Engineered Assemblies.
One 3.0 mm Monolithic Core.
A stone sheet alone is not a building envelope. Specify complete assemblies pairing our Class A2 3.0 mm modified-clay slabs with our two-component flexible adhesive (H01 emulsion + H02 mineral powder, 3–4.5 kg/m²), 45° bevel-mitered corners, and verified substrate details across walls, facades, curved columns, and wet zones.
01 / INTERACTIVE SYSTEM ASSEMBLIES
Select Your Building Envelope
Click any system below or inspect numbered cutaway pins (01–05) to read layer specifications.
02 / ENGINEERING COMPARISON MATRIX
Four Systems, Side by Side
Compare adhesive chemistry, joint allowances, cold-forming limits, and waterproofing requirements at a glance. Click any system header to load its 3D cutaway above.
| ENGINEERING PARAMETER | ||||
|---|---|---|---|---|
| Application Scope | Dry vertical interior walls, lobbies & feature walls | Exterior building facades & perimeter walls | Curved vertical walls & columns (No overhead ceilings) | Walk-in showers, bathrooms & thermal spa walls |
| Two-Component Adhesive & Rate | Two-Component H01 Emulsion + H02 Powder · 3–4.5 kg/m² | Two-Component H01 Emulsion + H02 Powder · 3–4.5 kg/m² (IMO Non-DG) | Two-Component H01 Emulsion + H02 Powder · 3–4.5 kg/m² | Two-Component H01 Emulsion + H02 Powder · 3–4.5 kg/m² over membrane |
| Notch Trowel & Bond Line | 4–6 mm V/U-Notch · ~1.5 mm compressed | 4–6 mm V/U-Notch · ~1.5 mm compressed | 4–6 mm V/U-Notch · ~1.5 mm compressed | 4–6 mm V/U-Notch · ~1.5 mm compressed |
| Standard Slab Formats | 1200×3000 / 1200×2400 / 600×1200 mm | 600×1200 / 1200×2400 mm modular | 1200×2400 / 600×1200 mm vertical grain | 1200×2400 / 600×1200 mm |
| Joint & Expansion Strategy | 0–1 mm tight, 2–3 mm grout, or 3–6 mm metal reveal | 6–10 mm flexible grout + PE rod silicone expansion joints | 0–1 mm tight seam or 2–3 mm color-matched grout | 2–3 mm anti-mold grout + 3 mm sanitary silicone corners |
| Corner & Edge Termination | 45° bevel-miter corner + color-matched grout | 45° bevel-miter + frameless direct-bond edge (no brackets) | Continuous radius wrap · 45° miter at flat returns | 45° bevel-miter outside · sanitary silicone inside corners |
| Curving & Forming Rule | Flat / minor wall undulations | Gentle architectural curves (ambient cold-press) | Ambient cold-press R ≥ 150 mm (no heat gun); 3D fluted vertical-rib axis only | Ambient cold-press over tanked curved shower walls |
| Waterproofing & Sealer | Unsealed raw mineral ex-factory · Sealer optional on request | Alkali primer below · Unsealed mineral face (sealer optional) | Interface primer below · Unsealed raw mineral ex-factory | 2-coat liquid membrane + corner mesh below · Sealer optional only |
02B / LAB-VERIFIED PERFORMANCE · CNAS / ILAC-MRA (JC/T 2219-2014)
Accredited Material & Export Compliance Data
Closed-cup flash point >70°C (non-flammable) · Not classified as dangerous goods for ocean shipping.
100% inorganic mineral pigments & mineral-oxide inks resist UV bond breakdown unlike organic dyes — achieving Grade 1 colorfastness and zero chalking, blistering, or cracking across 3,000h aging.
Passed 30 freeze-thaw cycles down to -30°C without cracking, chalking, or delamination.
Ultra-low TVOC (<8% of standard limit); soluble lead & cadmium below 0.1 mg/m² detection.
10× below Class A residential radiation limits — safe for enclosed bedrooms, spas & lobbies.
Breathable inorganic mineral matrix with zero blistering, cracking, or delamination.
High-precision factory cut tolerance (limit ±1 mm) and 0.12% thermal dimensional shift (≤0.5%).
Top Grade 1 stain resistance on textured stone, 0.29 mm indentation, and zero acid/alkali degradation.
03 / STANDARD ARCHITECTURAL DETAILS · SCALE 1:2 / 1:5
Construction Node Plates & Substrate Matrix
True cross-section drafting plates prepared for architects, specifiers, and site contractors. Click any plate to inspect enlarged scale geometry.
03B / EXISTING SUBSTRATE PREPARATION MATRIX
Site Readiness Rules for Renovation & New Build
Thoroughly degrease and wash glaze clean; repair any hollow tiles; roll dedicated tile bonding / quartz interface primer before thin-bed adhesive.
APPLIES TO: SYS 01 · SYS 02 · SYS 04Scrape away all flaking, chalking, or glossy latex paint (never bond over loose paint film); abrade/scarify sound wall and apply penetrating consolidating primer.
APPLIES TO: SYS 01 · SYS 03Verify bond soundness via pull-off check; patch hollow stucco and level ≥3 mm undulations; apply alkali-resistant consolidating primer before two-component H01 + H02 adhesive.
APPLIES TO: SYS 02Remove formwork release oils, dust, and surface laitance; dampen or apply interface primer depending on suction rate before notched adhesive.
APPLIES TO: SYS 01 · SYS 02 · SYS 03Tape board joints, apply primer, and install continuous 2-coat liquid flexible waterproofing membrane with fiberglass reinforcing tape at all inside corners.
APPLIES TO: SYS 04Verify rigid multi-ply curved framing without flex bounce; seal wood fibers with moisture-blocking interface primer prior to two-component H01 + H02 adhesive.
APPLIES TO: SYS 03 (Dry Interior)04 / SPECIFICATION & MATERIAL TAKEOFF
Send Us Your Wall Elevation & Substrate Photo.
Our specification desk responds within 2 hours with exact slab yield, scene-matched adhesive tonnage (calculated at 3–4.5 kg/m²), primer spec, and corner detailing guidance.